PORTABLE RADIANT HEATERS

PORTABLE RADIANT MH35LP FAQs


The burner will not light.

Check propane supply tank and connection to the tank to be sure it is tight.

If it is a new propane tank or just a refilled tank, slowly open the propane tank valve all the way, so you don't activate the excess flow valve which reduces or stops flow of LP in hose.

The unit will not stay lit after lighting pilot and I followed the lighting instructions?

Check connections to tip switch. If good remove wires from the tip switch and using a paper clip connect the two red wire connections together coming off the tip switch to bypass the tip switch. If this works replace tip switch.

After lighting the burner and holding the safety control valve in for 30 seconds the flame goes out when I release the safety control valve.

Check to be sure the connection from the thermocouple to the safety control valve is tight. If pilot still goes out you may have to replace the thermocouple or the control valve.

PORTABLE RADIANT MH125LP/NG FAQs


The burner will not light.

Check propane supply tank and connection to the tank to be sure it is tight.

If it is a new propane tank or just a refilled tank, slowly open the propane tank valve all the way, so you don't activate the excess flow valve which reduces or stops flow of LP in hose.