FORCED AIR PROPANE HEATERS

The Propane Forced Air Heaters now come standard with Quiet Burner Technology - running 50% quieter than standard forced air heaters. Heavy-duty design built for the jobsite. The heater comes with a standard 10ft hose and regulator and all the safety you would expect of a Mr. Heater product. Equipped with factory installed high limit switches and thermoelectric safety valves, you can feel comfortable using these heaters on any jobsite. Just plug the heater into a 110v outlet, hook up the included hose and regulator to a 20lb propane tank or larger, and you are ready to take the chill out of any job.

SITE CONTENT

Forced Air Propane FAQs

Forced Air Propane Manuals and Troubleshooting Guides

Forced Air Propane Heaters

FORCED AIR PROPANE HEATERS FAQs


The motor starts on my heater but no heat comes out?

Check to see that your propane supply tank is turned on. Listen for the sound of the spark igniter, it should make a fast ticking sound (Piezo igniter for the 35CLP so only one spark), if it doesn't replace igniter.

How long does it take to charge the battery? How long is the run time?

MH35CLP charge time is 5 hrs. MH60CLP charge time is 1battery (5hrs) 2 batteries (6hrs). MH35CLP run time is 8hrs. MH60CLP run time is 1 battery (4hrs) 2batteries (8hrs).

What is the maintenance for the rechargeable battery during the summer season?

It is recommended that the internal battery be maintained on a constant maintenance charge by leaving it plugged into a 120V power source. If constant maintenance charging is not possible, it is recommended that the battery be fully charged every 3 months.

What is the part number for the replacement battery?

The part number is F227964 and you can order it at mrheater.com.

The motor starts on my heater but no heat comes out?

Check to see that your propane supply tank is turned on. Listen for the sound of the spark igniter, it should make a fast ticking sound, if it isn't you will need to call technical support for some additional trouble shooting help.

Why does my heater only run for a few minutes and than the shuts off?

You need to have the correct sized tank for the heater you are using. For every 50,000 Btu output you need a minimum of a 20 to 40 pound LP tank. In below freezing weather you may need to double the size of your propane source to maintain sufficient volume of flow for correct heater operation.

My heater has started giving off a bad smell?

There are different types of chemicals that, when drawn into the heater during its burning will react with the propane and make some disagreeable odors. The propane supplier may have added more of the orderizor to propane. First try the heater in a different area where no chemicals are used to see if the smell goes away and also try a different propane tank.

Can I convert this heater to natural gas?

Unfortunately, no. These heaters are set up to run Propane only. There are no available conversion kits.

Why does my heater not spark?

Usually the igniter itself needs cleaned with steel wool and readjusted. The igniter should be a 1/4in away form the orifice assembly. If this does not fix the issue, then make sure there is power going to the assembly. If so then the igniter is possibly bad or the board is bad. Please contect Technical Service or enter your serial number below at the base of the page to utilize the Interactive Schematic.

Is this heater indoor safe?

These heaters are outdoor only heater though they may be used in a garage setting or construction setting with proper ventilation. Standard ventilation is 1 square inch per 1000 BTUs. These heaters only have a thermocouple and high limit sensor but no ODS (Oxygen Depletion Sensor) so there is no way for the heater to know if its operating at dangerous O2 levels.

FORCED AIR PROPANE HEATER MANUAL AND TROUBLESHOOTING GUIDE